Parameter Prerequisite Description User interface Factory setting
NSV flow For the following order code:
"Application package", option
EJ "Petroleum"
The API referenced
correction option is selected
in Petroleum mode
parameter.
The software options
currently enabled are
displayed in the
Software option
overview parameter.
Displays the net volume flow
which is calculated from the
measured total volume flow
minus the value for sediment
& water and minus the
shrinkage.
Dependency
The unit is taken from:
Corrected volume flow unit
parameter
Signed floating-point
number
NSV flow alternative For the following order code:
"Application package", option
EJ "Petroleum"
In the Petroleum mode
parameter, the API
referenced correction
option is selected.
The software options
currently enabled are
displayed in the
Software option
overview parameter.
Displays the net volume flow
which is calculated from the
measured alternative total
volume minus the value for
sediment & water and minus
the shrinkage.
Dependency
The unit is taken from:
Corrected volume flow unit
parameter
Signed floating-point
number
Oil CTL For the following order code:
"Application package", option
EJ "Petroleum"
In the Petroleum mode
parameter, the Net oil &
water cut option is selected.
The software options
currently enabled are
displayed in the
Software option
overview parameter.
Displays the correction factor
which represents the effect of
temperature on the oil. This is
used to convert the measured
oil volume flow and the
measured oil density to values
at reference temperature.
Positive floating-
point number
Oil CPL For the following order code:
"Application package", option
EJ "Petroleum"
In the Petroleum mode
parameter, the Net oil &
water cut option is selected.
The software options
currently enabled are
displayed in the
Software option
overview parameter.
Displays the correction factor
which represents the effect of
pressure on the oil. This is
used to convert the measured
oil volume flow and the
measured oil density to values
at reference pressure.
Positive floating-
point number
Oil CTPL For the following order code:
"Application package", option
EJ "Petroleum"
In the Petroleum mode
parameter, the Net oil &
water cut option is selected.
The software options
currently enabled are
displayed in the
Software option
overview parameter.
Displays the combined
correction factor which
represents the effect of
temperature and pressure on
the oil. This is used to convert
the measured oil volume flow
and the measured oil density
to values at reference
temperature and reference
pressure.
Positive floating-
point number