Epson Artisan 810/835/837/710/725/730/Epson Stylus Photo PX810FW/TX810FW/PX820FWD/TX820FWD/PX830FWD/PX710W/TX710W/PX720WD/TX720WD/PX730WD/TX730WD
Revision G
Artisan 837/730/PX830FWD/PX730WD/TX730WD
Disassembly/assembly 305
Confidential
After installing the Document Cover Open Sensor, make sure
the Document Cover Detector Plate shown in
Fig. 9-31 is on the
lever of the Document Cover Open Sensor.
Figure 9-31. Installing the Document Cover Open Sensor
Refer to the following when routing the Document Cover Open
Sensor cable and grounding wire.
Artisan 837/PX830FWD
• Route the Document Cover Open Sensor cable through the
rib A (x2), inside the rib B (x8) and rib C (x1) of the Scanner
Lower Housing, and then route it through the hole of the
Scanner Lower Housing.
• Make sure to route the grounding wire through the rib A
(x1).
Figure 9-32. Routing the Document Cover Open Sensor Cable/
Grounding Wire (1)
Lever of the Document
Cover Open Sensor
Document Cover Detector Plate
Rib A
Rib B
Rib C
Document Cover
Open Sensor cable
Hole of Scanner Lower Housing
Grounding wire
Scanner Lower Housing
Artisan 730/PX730WD/TX730WD
• Route the Document Cover Open Sensor cable through the
rib A (x1), inside the rib B (x10) and rib C (x2) of the
Scanner Lower Housing, and then route it through the hole
of the Scanner Lower Housing.
Figure 9-33. Routing the Document Cover Open Sensor Cable/
Grounding Wire (2)
Hole of Scanner Lower Housing
Scanner Lower Housing
Rib A
Rib B
Rib C
Document Cover
Open Sensor cable