Symptom
White or black (dark) bands occur in the horizontal direction on images.
Figure 4-6. White or black bands
Cause
Rear Unit installation failure
Paper settings of main unit or printer driver settings are inappropriate.
Nozzles missing
Adjustment values are inappropriate
Paper skewed
Sub scanning line (feed) direction
Main scanning line (CR operation) direction