22 UMG70XV3-4EN 12.01.2009
2 Safety Instructions according to Directive 94/9/EC
Type **K1N73, **G1N73, **H1N73
manufacturer FLEXIM GmbH, Wolfener Str. 36, 12681 Berlin
marking
0044;
Ex e q II T6...T3
Ex tD A21 IP65 TX
certification IBExU07ATEX1168 X
IECEx IBE08.0007X
type of protection transducer: powder filling
transducer connection: increased safety
dust: protection by enclosure tD
degree of protection IP 65 according to EN 60529
explosion protection
temperature according
to ATEX
temperature class T3: -40…+140 °C
temperature class T4: -40…+125 °C
temperature class T5: -40…+90 °C
temperature class T6: -40…+75 °C
Type **K1N83, **G1N83, **H1N83, **M1N83, **P1N83, **Q1N83
manufacturer FLEXIM GmbH, Wolfener Str. 36, 12681 Berlin
marking
0044;
Ex e q II T6...T3
Ex tD A21 IP65 TX
certification IBExU07ATEX1168 X
IECEx IBE08.0007X
type of protection transducer: powder filling
transducer connection: increased safety
dust: protection by enclosure tD
degree of protection IP 65 according to EN 60529
explosion protection
temperature according
to ATEX
temperature class T3: -55…+140 °C
temperature class T4: -55…+125 °C
temperature class T5: -55…+90 °C
temperature class T6: -55…+75 °C
II2G