EasyManua.ls Logo

Flintec FT-111 - Page 94

Flintec FT-111
137 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FT-111, User Manual Rev. 2.0.0, June 2022 Page 94 of 137
B1
0 No Error
1 In programming mode
B2
0 No Error
1 System error
B3
0 No Error
1 ADC under range
B4
0 No Error
1 ADC over range
B5
0 No Error
1 ADC out of range
B6
0 No Error
1 Tilt Switch is active
B7 B31
Not used
40011
R
2
Heartbeat for connection checking, this value is increased every 100
milliseconds.
40013
R
2
Last print value
40015
R/W
2
CN (Label number)
Refer to parameter [254] on page 57.
40017-24
R
8
Not used
40025
R/W
2
Commands
Dec
Definition
0
None
1
Zero
2
Tare
3
Clear
4
Print
5
Not used
6
High resolution enable
7
High resolution disable
8
Unit change (from first to second unit)
9
Unit change (from second to first unit)
10
Keylock enable
11
Keylock disable
28
Read stable weight and Record to Alibi
40027
R
2
Commands
status
0
None
1
2
Command is successfully.
3
Command failed.
40029
R/W
12
Not used
40041
R
2
Status of Inputs
Bit
Definition
B0
Input-1
0 Passive
1 Active
B1
Input-2
B2
Input-3
B3
Input-4
40043
R/W
2
Status of Outputs
B0
Output-1
0 Passive
1 Active
B1
Output-2
B2
Output-3
B3
Output-4
B4
Output-5
40045
R/W
2
Setpoint 1
40047
R/W
2
Setpoint 2
40049
R/W
2
Setpoint 3
40051
R/W
2
Setpoint 4
40053
R/W
2
Setpoint 5
40057
R/W
30
Reserve
40087
R
2
Alibi number
40089
R
2
Net weight
40091
R
2
Tare weight

Table of Contents

Related product manuals