6100B/6105A
Users Manual
3-10
3-9. Switch to the Current Output
The focus must be on the current channel to set it up. After power up the Menu focus will
be on the Waveform Menu (blue border).
1. Push (or F9) once to move the focus to the Output Menu.
2. Use to change the Output Menu control focus to L1 current (L1 I). Note the
white background shifts to the active channel. Leave the focus on L1 current. See
Figure 3-4.
gdw10a.bmp
Figure 3-4. The Output Menu (L1 Current Selected)
3-10. Enable the Current Channel
A channel must be enabled before an output is placed at the Instrument binding posts.
Both the L1 voltage and current channels both show “Disabled”. Before an output can
appear at the output terminals the relevant channel must be “Enabled”.
When the Output Menu has focus you can enable the L1 current channel using the
softkeys. See Figure 3-5.
Note
If in the future the Menu focus is on the Output Menu but the softkeys are
not as expected, push to move up to the next softkey level. Pushing
then has no effect once the top level is reached.
gdw06a.bmp
Figure 3-5. The Output Menu Softkeys