CFM Configuration
237
Table 31-11 Configuration continuity detection
Operation
Command
Remarks
Enter global configuration mode
configure terminal
-
To maintain the domain
configuration mode to enter
cfm md md-index
-
Enter the configuration mode
set to maintain
cfm ma ma-index
-
Configuration maintenance
interval endpoint to send the
CCM
cfm cc interval {1 | 10 | 60 | 600}
Optional
The default
value is 1s
Enable sending MEP ccm
cfm mep mep-id cc {enable | disable}
Required
Default is off
Caution:
Different devices at the same maintenance domain and maintain a centralized
maintenance endpoint, the sending time interval of CCM must be the same.
31.2.10 Configure Loopback
By configuring the loopback function, you can check the source to the target MEPs MEPs
or MIPs link between the situations in order to achieve the link connectivity verification.
Table 31-12 Configure loopback
Operation
Command
Remarks
Enter global configuration mode
configure terminal
-
To maintain the domain
configuration mode to enter
cfm md md-index
-
Enter the configuration mode set
to maintain
cfm ma ma-index
-
Start loopback
cfm loopback mep mep-id {dst-mac
mac-address | dst-mep rmep-id} [priority
pri-id | count pkt-num | length data-len |
data pkt-data]
Optional
31.2.11 Configure Link Tracking
By configuring the link tracking, you can find the source to the target MEPs MEPs or
maintenance intermediate point between the paths in order to achieve the positioning of link
failure.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FoxGate S6424-S2C2 series and is the answer not in the manual?

FoxGate S6424-S2C2 series Specifications

General IconGeneral
BrandFoxGate
ModelS6424-S2C2 series
CategorySwitch
LanguageEnglish

Related product manuals