ARP Configuration
85
threshold
By default, the safety
trigger threshold 16PPS
Configure approach for
the attacker
arp anti-flood action {deny-arp|deny-all}
threshold threshold
optional
By default,for the
attacker's approach to
deny ARP
Configure automatically
banned user recovery
time
arp anti-flood recover-time time
optional
Configurable time range
is <0-1440> minutes, set
to 0, said to be manually
restored.
By default,the user
automatically banned
recovery time of 10
minutes.
Banned user manual
resume forwarding.。
arp anti-flood recover {H:H:H:H:H:H | all}
optional
12.3.4 Displaying and Maintain against ARP Flood
Table 12-6
Operation
Command
Remark
Display ARP anti-flood configuration and
attackers list
show arp anti-flood
Perform either of the
commands