106 Upgrade and Maintenance Manual BX924 S4
Hard disk drives / Solid state drives
© cognitas. Gesellschft für Technik-Dokumentation mbH 2013 Pfad: C:\Programme\FCT\tim_app\tim_local\work\PICHOL\OBJ_DOKU-20565-001.fm
Installing HDD/SSD 1 on top of the heat sink of CPU 2
The following figure shows the connector for HDD/SSD 1 on the mounting
frame (see arrow).
Figure 23: Connector for HDD/SSD 1 on top of the heat sink for CPU 2
Figure 24: Mounting the HDD/SSD 1 into its location
Ê Slide the mounting kit into the cut-out (1) of the mounting platform.
Ê Plug the mounting kit into the connector (see arrow in figure 23) for
HDD/SSD 1 on the mounting platform (2).
Ê Secure the mounting kit with the knurled screw (3). Torque: 0.2 Nm (not
applicable for the Japanese market)