Ê Open the server blade as described in section "Opening the server blade"
on page 55.
Ê Turn switch 3 of the user DIP switch bank to OFF, see section "Onboard
settings" on page 279.
Ê Close the server blade as described in section "Closing the server blade" on
page 56.
Ê Reinstall the server blade in the system unit as described in section
"Installing the server blade in the system unit" on page 57.
Ê Switch on the server blade as described in section "Switching on the server
blade" on page 60.
Ê You can now put the server blade back into operation.
5.2.1.2 Updating or recovering the iRMC
TFTP update procedure
Ê Login to the management blade web interface.
Ê Open the Information / Operation – Operation – Firmware Update menu.
Ê Open the Server Blade tab.
Ê In the Server Blade to be Updated box select the desired server.
Ê In the Update settings box enter the TFTP IPv4 or IPv6 address of the TFTP
server and the pathname of the TFTP firmware file.
I For more detailed information, refer to the Help – On Page function of
the management blade web interface.
Ê Click the Apply button to start the update process.
The status column in the Server Blade to be Updated box provides information
on the update progress.
V CAUTION!
Do not interrupt the iRMC upgrade process after it has started. If the
process is interrupted, the iRMC may be permanently corrupted.