BX924 S4 Upgrade and Maintenance Manual 145
Mezzanine cards
Ê Shut down the defective server blade as described in section "Shutting down
the server blade" on page 52.
Ê Locate the defective mezzanine card using the onboard Local Diagnostic
LEDs as described in section "Onboard indicators and controls" on
page 280.
7.4.3 Removing a mezzanine card
Ê Remove the defective mezzanine card as described in section "Removing a
mezzanine card" on page 141.
7.4.4 Installing a mezzanine card
Ê Install the new mezzanine card as described in section "Installing a
mezzanine card" on page 135.
7.4.5 Concluding steps
I If applicable, reconfigure your network settings in the operation system
according to the original configuration of the replaced controller
(expansion card or onboard CNA). For further information, please refer
to section "Note on network settings recovery" on page 144.
Perform the following procedures to complete the task:
Ê Close the server blade as described in section "Closing the server blade" on
page 56.
Ê Reinstall and secure the server blade in the system unit as described in
section "Installing the server blade in the system unit" on page 57.
Ê If applicable, close the rack door as described in section "Closing the rack
door" on page 62.
Ê Enable the PCI slot of the replaced mezzanine card as described in section
"Enabling replaced components in the system BIOS" on page 85.
Ê Inform the customer about changed WWN and MAC addresses. For further
information, refer to section "Looking up changed MAC / WWN addresses"
on page 92.