286 Upgrade and Maintenance Manual BX924 S4
Appendix
© cognitas. Gesellschft für Technik-Dokumentation mbH 2013 Pfad: C:\Programme\FCT\tim_app\tim_local\work\PICHOL\OBJ_DOKU-20571-001.fm
12.4 Minimum startup configuration
If the server blade does not start up or other problems occur, it may be
necessary to take the system down to its most basic configuration in order to
isolate the defective component.
The minimum startup configuration consists of the following components:
Ê Shut down the server blade as described in section "Shutting down the
server blade" on page 52.
Ê Remove the server blade from the system unit as described in section
"Removing a server blade" on page 53.
Ê Take the server blade down to its minimum startup configuration.
Ê Reinstall the server blade in the system unit as described in section
"Installing the server blade in the system unit" on page 57.
Ê Switch on the server blade as described in section "Switching on the server
blade" on page 60.
Ê Login to the management blade web interface, see section "Accessing the
management blade web interface" on page 41.
Field Replaceable Units (FRU)
Component Notes and reference
BX924 S4 server blade
1 CPU with heat sink
Installed in slot CPU 1, see section "Basic
information" on page 97.
1 memory module
Installed in socket DIMM 1A, see section
"Basic information" on page 148.
Table 7: Minimum startup configuration - components

Table of Contents