BX924 S4 Upgrade and Maintenance Manual 235
System board components
Ê If BitLocker functionality is used and has been disabled before starting the
maintenance task, re-enable BitLocker as described in section "Enabling
BitLocker functionality" on page 91.
10.2.1.5 Software configuration
The UFM delivery set includes the "Recovery Tool CD" to setup the ESXi
configuration. Proceed as follows:
Ê Switch on the server blade.
Ê Right after switching on the server, insert the "Recovery Tool CD" into the
DVD drive and close the drive tray.
Ê The server should now boot from the "Recovery Tool CD".
Ê Follow the on-screen instructions.
10.2.2 Removing the UFM
10.2.2.1 Required tools
Preliminary and concluding steps: tool-less
Removing the UFM:
Phillips PH0 / (+) No. 0 screw driver
Field Replaceable Units (FRU)
Average hardware task duration: 5 minutes
Average software task duration: 5 minutes