BX924 S4 Upgrade and Maintenance Manual 139
Mezzanine cards
7.2.4 Concluding steps
Perform the following procedures to complete the task:
Ê Close the server blade as described in section "Closing the server blade" on
page 56.
Ê Reinstall and secure the server blade in the system unit as described in
section "Installing the server blade in the system unit" on page 57.
Ê Update the firmware as described in section "Updating mezzanine card
firmware" on page 78.
Ê In order to configure a mezzanine card that has been installed or replaced,
the card’s Option ROM has to be enabled in the system board BIOS. For
SAN / iSCSI boot the card's Option ROM has to be enabled permanently. If
applicable, proceed as described in section "Enabling Option ROM scan" on
page 80.
Ê Enable boot watchdog functionality as described in section "Enabling boot
watchdog functionality" on page 84.
Ê If BitLocker functionality is used and has been disabled before starting the
maintenance task, re-enable BitLocker as described in section "Enabling
BitLocker functionality" on page 91.
Ê If applicable, restore LAN teaming configurations as described in section
"After replacing / upgrading LAN/CNA controllers" on page 94.