114 Upgrade and Maintenance Manual BX924 S4
Hard disk drives / Solid state drives
© cognitas. Gesellschft für Technik-Dokumentation mbH 2013 Pfad: C:\Programme\FCT\tim_app\tim_local\work\PICHOL\OBJ_DOKU-20565-001.fm
6.5 Replacing a HDD/SSD
V CAUTION!
All HDD/SSD (drives) must be uniquely identified so that they can be
reinstalled in their original mounting locations later. If this is not done,
existing data can be lost.
6.5.1 Required tools
Preliminary and concluding steps: tool-less
Replacing a HDD/SSD: Phillips PH2 / (+) No. 2 screw driver
6.5.2 Preliminary steps
Before replacing a HDD/SSD, perform the following steps:
Ê Disable BitLocker functionality as described in section "Disabling BitLocker
functionality" on page 66.
Ê If applicable, open the rack door as described in section "Opening the rack
door" on page 51.
Ê Locate the desired server blade as described in section "Locating the
defective server blade" on page 43.
Ê Shut down the server blade as described in section "Shutting down the
server blade" on page 52.
Ê Remove the server blade from the system unit as described in section
"Removing the server blade from the system unit" on page 54.
Ê Open the server blade as described in section "Opening the server blade"
on page 55.
Upgrade and Repair Units (URU)
Average hardware task duration: 15 minutes
Average software task duration: 5 minutes