162 Upgrade and Maintenance Manual BX924 S4
Main memory
© cognitas. Gesellschft für Technik-Dokumentation mbH 2013 Pfad: C:\Programme\FCT\tim_app\tim_local\work\PICHOL\OBJ_DOKU-20567-001.fm
Figure 55: Securing the memory module
Ê Press down on the memory module (1) until the securing clips snap into the
cutouts at each end of the module (2).
8.2.4 Concluding steps
Perform the following procedures to complete the task:
Ê If applicable, reinstall the air cowls as described in section "Installing the air
cowls" on page 170.
Ê If applicable, reinstall the mezzanine carrier as described in section
"Installing mezzanine cards" on page 134.
Ê Close the server blade as described in section "Closing the server blade" on
page 56.
Ê Reinstall and secure the server blade in the system unit as described in
section "Installing the server blade in the system unit" on page 57.
Ê If applicable, close the rack door as described in section "Closing the rack
door" on page 62.
Ê If available, update the system board BIOS to the latest version as described
in section "Updating or recovering the system board BIOS and iRMC" on
page 73.