108 Upgrade and Maintenance Manual BX924 S4
Hard disk drives / Solid state drives
© cognitas. Gesellschft für Technik-Dokumentation mbH 2013 Pfad: C:\Programme\FCT\tim_app\tim_local\work\PICHOL\OBJ_DOKU-20565-001.fm
6.4 Removing HDD/SSD
6.4.1 Required tools
● Preliminary and concluding steps: tool-less
● Removing a HDD/SSD module:
– Phillips PH2 / (+) No. 2 screw driver
6.4.2 Preliminary steps
Before removing a HDD/SSD module, perform the following steps:
Only applicable for removing intact HDD/SSD modules:
Ê Ensure that the HDD/SSD module to be removed is not combined into a
RAID array. If the drive is part of a RAID array, you first need to delete the
array using ServerView RAID Manager.
V CAUTION!
All data on all HDDs/SSDs in the array will be lost! Be sure to back up
your data before deleting a RAID array.
I For further information, please refer to the "ServerView Suite RAID
Management" user guide, available online.
Ê If applicable, open the rack door as described in section "Opening the rack
door" on page 51.
Ê Locate the desired server blade as described in section "Locating the
defective server blade" on page 43.
Ê Shut down the server blade as described in section "Shutting down the
server blade" on page 52.
Upgrade and Repair Units (URU)
Average task duration: 15 minutes