EasyManua.ls Logo

Fujitsu PRIMERGY BX924 S4

Fujitsu PRIMERGY BX924 S4
286 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
108 Upgrade and Maintenance Manual BX924 S4
Hard disk drives / Solid state drives
© cognitas. Gesellschft für Technik-Dokumentation mbH 2013 Pfad: C:\Programme\FCT\tim_app\tim_local\work\PICHOL\OBJ_DOKU-20565-001.fm
6.4 Removing HDD/SSD
6.4.1 Required tools
Preliminary and concluding steps: tool-less
Removing a HDD/SSD module:
Phillips PH2 / (+) No. 2 screw driver
6.4.2 Preliminary steps
Before removing a HDD/SSD module, perform the following steps:
Only applicable for removing intact HDD/SSD modules:
Ê Ensure that the HDD/SSD module to be removed is not combined into a
RAID array. If the drive is part of a RAID array, you first need to delete the
array using ServerView RAID Manager.
V CAUTION!
All data on all HDDs/SSDs in the array will be lost! Be sure to back up
your data before deleting a RAID array.
I For further information, please refer to the "ServerView Suite RAID
Management" user guide, available online.
Ê If applicable, open the rack door as described in section "Opening the rack
door" on page 51.
Ê Locate the desired server blade as described in section "Locating the
defective server blade" on page 43.
Ê Shut down the server blade as described in section "Shutting down the
server blade" on page 52.
Upgrade and Repair Units (URU)
Average task duration: 15 minutes

Table of Contents

Related product manuals