226 Upgrade and Maintenance Manual BX924 S4
System board components
© cognitas. Gesellschft für Technik-Dokumentation mbH 2013 Pfad: C:\Programme\FCT\tim_app\tim_local\work\PICHOL\OBJ_DOKU-20569-001.fm
Do not throw batteries into the trash can. Lithium batteries must be
disposed of in accordance with local regulations concerning special
waste.
For further safety information, please refer to section "Environmental
protection" in the PRIMERGY BX924 S4 Operating Manual.
Ensure to insert the CMOS battery with the positive pole facing
up!
10.1.1 Required tools
Preliminary and concluding steps:
Phillips PH2 / (+) No. 2 screw driver
Replacing the battery: tool-less
10.1.2 Preliminary steps
Before replacing the CMOS battery, perform the following steps:
Ê If applicable, open the rack door as described in section "Opening the rack
door" on page 51.
Ê Locate the desired server blade as described in section "Locating the
defective server blade" on page 43.
Ê Shut down the server blade as described in section "Shutting down the
server blade" on page 52.
Ê Remove the server blade from the system unit as described in section
"Removing the server blade from the system unit" on page 54.
Ê Open the server blade as described in section "Opening the server blade"
on page 55.