174 Upgrade and Maintenance Manual BX924 S4
Processors
© cognitas. Gesellschft für Technik-Dokumentation mbH 2013 Pfad: C:\Programme\FCT\tim_app\tim_local\work\PICHOL\OBJ_DOKU-20568-001.fm
9.1 Basic information
The system board D3143 offers two sockets for Intel Xeon processors.
Supported processors
CPU: Intel Xeon processor E5-2600v2 family
Socket type: LGA 2011 package
Thermal Design Power (TDP) class: up to 130 W
9.2 Installing processors
V CAUTION!
Processors are extremely sensitive to electrostatic discharge and must
be handled with care. After a processor has been removed from its
protective sleeve or from its socket, place it upside down on a
nonconducting, antistatic surface. Never push a processor over a
surface.
9.2.1 Required tools
Preliminary and concluding steps: tool-less
Removing and installing the processor heat sink:
Phillips PH2 / (+) No. 2 screw driver
Installing the processor: tool-less
Field Replaceable Units (FRU)
Average hardware task duration: 15 minutes