BX924 S4 Upgrade and Maintenance Manual 115
Hard disk drives / Solid state drives
Ê Locate the defective HDD/SSD module as described in section "Locating the
defective component" on page 48.
Only applicable for removing intact HDD/SSD:
Ê Before removing a non-defective HDD/SSD, put the drive into "Offline" mode
using your RAID configuration software.
6.5.3 Removing a HDD/SSD 1
Ê Remove the HDD/SSD 1 to be replaced from the server as described in
section "Removing SSD 0" on page 109.
6.5.4 Installing a HDD/SSD 1
Ê Install the new HDD/SSD 1 into the empty drive bay as described in section
"Installing SSD 0" on page 101.
6.5.5 Concluding steps
Perform the following procedures to complete the task:
Ê Close the server blade as described in section "Closing the server blade" on
page 56.
Ê Reinstall and secure the server blade in the system unit as described in
section "Installing the server blade in the system unit" on page 57.
Ê If applicable, close the rack door as described in section "Closing the rack
door" on page 62.
Ê Please observe the notes on RAID rebuild in section "Performing a RAID
array rebuild" on page 92.
Ê If BitLocker functionality is used and has been disabled before starting the
maintenance task, re-enable BitLocker as described in section "Enabling
BitLocker functionality" on page 91.