82 Upgrade and Maintenance Manual BX924 S4
Basic software procedures
© cognitas. Gesellschft für Technik-Dokumentation mbH 2013 Pfad: C:\Programme\FCT\tim_app\tim_local\work\PICHOL\OBJ_DOKU-20564-001.fm
Re-enabling backup drives
If a backup drive has been disabled or deleted from the backup software drive
list as described in section "Verifying and configuring the backup software
solution" on page 69, it has to be re-enabled to complete the maintenance task.
Ê Re-enable backup drives and revise backup software settings and cronjobs.
I Detailed information on suitable backup software solutions and
related documentation is available to Fujitsu service partners from the
Fujitsu Extranet pages
5.2.7 Resetting the boot retry counter
The boot retry counter is decremented from its preset value every time the
POST watchdog initiates a system reboot. When the value has reached ’0’, the
system will shut down and power off.
5.2.7.1 Viewing the boot retry counter
The current boot retry counter status is available in the management blade web
interface:
Ê Enter the management blade web interface.
Ê Open the Components System Server Blades Server Blade-x menu for the
desired server blade.
Ê Select the Configuration tab and scroll to the ASR box.
Ê Under Retry Counter 0-max. the current number of remaining boot attempts is
displayed. The value is further decremented with every failed boot attempt
or system reboot resulting from critical system errors.
5.2.7.2 Resetting the boot retry counter
The boot retry counter should be reset to its original value concluding every
service task.
I Please note, if the customer does not know about the original boot
retry values: