2.1 PLC Connection 2-1
2.1 PLC Connection
Serial Connection
*1 Can be connected using the AB’s “1756-CP3” cable + D-sub gender changer (9-pin, female-to-male) commercially available.
*2 Use a D-sub gender changer (9-pin, female-to-male) commercially available.
*3 For the ladder transfer function, see the V9 Series Reference Manual.
Ethernet Connection
*1 For KeepAlive functions, see “1.3.2 Ethernet Communication”.
*2 For the ladder transfer function, see the V9 Series Reference Manual.
PLC Selection
on the Editor
CPU Unit/Port Signal Level
Connection
Ladder
Transfer
*3
CN1 MJ1/MJ2
PLC-5
PLC-5/10, PLC-5/12,
PLC-5/15, PLC-5/25
1785-KE RS-232C Wiring diagram 3 - C2 Wiring diagram 4 - M2
1770-KF2
RS-232C Wiring diagram 4 - C2 Wiring diagram 5 - M2
RS-422 Wiring diagram 2 - C4
PLC-5/11, PLC-5/20,
PLC-5/20E, PLC-5/30,
PLC-5/40, PLC-5/40L,
PLC-5/40E, PLC-5/60,
PLC-5/60L, PLC-5/80,
PLC-5/80E
Channel 0
RS-232C Wiring diagram 4 - C2 Wiring diagram 5 - M2
RS-422 Wiring diagram 3 - C4
1785-KE RS-232C Wiring diagram 3 - C2 Wiring diagram 4 - M2
1770-KF2
RS-232C Wiring diagram 4 - C2 Wiring diagram 5 - M2
RS-422 Wiring diagram 2 - C4
Control Logix /
Compact Logix
1756 Control Logix Logix 5550
RS-232C
Wiring diagram 1 - C2
*1
Wiring diagram 1 - M2
1769 Compact Logix Channel 0
SLC500 SLC5/03 and later
Channel 0 RS-232C
1747-KE DF1
RS-232C Wiring diagram 2 - C2 Wiring diagram 2 - M2
RS-422 Wiring diagram 1 - C4
MicroLogix
MicroLogix 1000
MicroLogix 1100
MicroLogix 1500
Channel 0 RS-232C
AB’s “1761-CBL-PM02”
+
Gender c h a nger
*2
AB’s “1761-CBL-PM02”
+
Wiring diagram 3 - M2
Manufacturer Model
Black Box FA440-R2
Misumi DGC-9PP
PLC Selection on the Editor CPU Unit TCP/IP UDP/IP Port No.
Keep
Alive
*1
Ladder
Transfer
*2
PLC-5 (Ethernet)
PLC-5/20E
PLC-5/40E
PLC-5/80E
- 44818 fixed
Control Logix (Ethernet)
Logix 5550 1756-ENBT/A
44818 fixed
1769-L32E
1769-L35E
1769-L27ERM-QBFC1B
*2
-
SLC500 (Ethernet TCP/IP) SLC 5/05
1747-L551
1747-L552
1747-L553
MicroLogix (Ethernet TCP/IP) MicroLogix 1100 -
NET-ENI
(SLC500 Ethernet TCP/IP)
SLC 5/03
SLC 5/04
SLC 5/05
1761-NET-ENI
1761-NET-ENI
W
Fixed to 44818
(Max. 6 units)
NET-ENI
(MicroLogix Ethernet TCP/IP)
MicroLogix 1000
MicroLogix 1100
MicroLogix 1200
MicroLogix 1500
1761-NET-ENI
1761-NET-ENI
W
Fixed to 44818
(Max. 6 units)