Chapter 4 Device Configuring Using the Front Panel Routing and Descrambling
© 2012 Harmonic Inc. 49 ProView 7000 v.2.6, Rev. E
❑ CAM 2
❑ CAM 3
12
❑ CAM 4
12
❑ None
■ Redundancy Triggers
❑ Sync Loss – Enable or disable, default is Enable.
❑ CC Errors – Enable or disable, default is Enable.
❑ PID Missing – Enable or disable, default is Enable.
❑ Thresholds
•Sync Loss
· Primary Duration – set the period that the state must exist to trigger redundancy
· Backup Duration – set the period that the state must exist to trigger redundancy
• CC Errors
· Primary Duration – set the period that the number of CC errors must occur within
to trigger redundancy
· Primary Counter – set the number of CC errors that must occur within a period to
trigger redundancy
· Backup Duration – set the period that the number of CC errors must occur within to
trigger redundancy
· Backup Counter – set the number of CC errors that must occur within a period to
trigger redundancy
• PID Missing
· PID– set the PID number
· Primary Duration – set the period that the PID must be missing for to trigger
redundancy
· Backup Duration – set the period that the PID must be missing for to trigger
redundancy
■ Input Type – Use this menu to select the input type MPEG or DVB.