Chapter 4 Device Configuring Using the Front Panel Routing and Descrambling
© 2012 Harmonic Inc. 49 ProView 7000 v.2.6, Rev. E
CAM 2
CAM 3
12
CAM 4
12
None
Redundancy Triggers
Sync Loss – Enable or disable, default is Enable.
CC Errors – Enable or disable, default is Enable.
PID Missing – Enable or disable, default is Enable.
Thresholds
•Sync Loss
· Primary Duration – set the period that the state must exist to trigger redundancy
· Backup Duration – set the period that the state must exist to trigger redundancy
CC Errors
· Primary Duration – set the period that the number of CC errors must occur within
to trigger redundancy
· Primary Counter – set the number of CC errors that must occur within a period to
trigger redundancy
· Backup Duration – set the period that the number of CC errors must occur within to
trigger redundancy
· Backup Counter – set the number of CC errors that must occur within a period to
trigger redundancy
PID Missing
· PID– set the PID number
· Primary Duration – set the period that the PID must be missing for to trigger
redundancy
· Backup Duration – set the period that the PID must be missing for to trigger
redundancy
Input Type – Use this menu to select the input type MPEG or DVB.