9
Operating instructions HERMA 400 O
PERATION (VIA THE HERMA 400 CONTROL)
3.28 US (130519) 105/154
9.5.5 Speed of the applicator (Quick Menu parameter)
030
36.0 m/min
Select
Range:
3–20, 3–30, 3–40, 3–80, , 0–120 m/min
With the help of this parameter the speed of the
label web can be adjusted. Minimum and maximum
speeds correspond to the performance of the drive used.
When using a master encoder this parameter will adjust the speed for manual feeding (after pressing
the
key
).
9.5.6 Speed of the product (Quick Menu parameter, optional)
035
120.0 m/min
Select
Range: Max. 120.0 m/min.
With the help of this parameter the speed
of the product to be labeled can be adjusted.
The speed can be adjusted, i.e. this parameter is available, for
all application types except for rigid
beak, pivot beak, and type 211.
When using a master encoder the product speed can only be read.
Specifying the product speed may be required if there is a difference between product and label
speeds
. In such case specifiying the product speed can ensure a highest possible positioning accuracy.
9.5.7 Conveyor speed 152 (036)
This parameter will appear only if parameter 201 (available only for Technical Service) is set to „CAN:
Type 152“.
The current conveyor speed with application type „152“.
9.5.8 Product speed transverse transfer system (037)
This parameter will appear only if parameter 201 (available only for Technical Service) is set to „X17:
Transverse unit“ or „CAN: Transverse unit“.
The product speed with applicat
ion type „Transverse unit“.
This value is required to convert start delay + activation time into a distance.