10
Cleaning, maintenance, service Operating instructions HERMA 400
132/154 3.28 US (130519)
10.1 Maintenance schedule
Recommended
interval
Maintenance task
Daily Dispensing beak / plate
Remove adhesive residue
Transport roller
Remove adhesive residue and clean.
For details see section 4.1.9, page 57.
Brake plate
Remove adhesive residue. For
details see section 4.1.4, page 40.
(Reversing) rollers
Remove adhesive residue
Label sensor
Clean the sensor (see separate instruction manual, if applicable)
Pivot beak / Application unit
Remove adhesive residue and clean.
For details see section 4.1.7, page 50.
Moving beak
Remove adhesive residue and clean.
For details see section 4.1.7, page 51.
Transverse transfer system
Remove adhesive residue and clean.
For details see section 4.1.8, page 55.
Weekly Housing
Clean display and housing
Pneumatic system (if applic
able)
Check air supply and components (see separate instruction manual, if
applicable)
Monthly Signal column (if applicable)
Check the bulbs
Every 5 years Check all pneumatic ho
ses for porosity and replace if needed (if
applicable)
Every 10 years Exchange all pneumatic hoses (if
applicable)
Generally,
depe
nding on
extent of use
The need for exchanging the toothed b
elt in the basic unit of the
applicator is to be reckoned with after approx. 50.000.000 to
100.000.000 labelling cycles
The pulleys of the st
andard rewinder are to be exchanged with every
second exchange of the corresponding belt