9
Operation (via the HERMA 400 control)
Operating instructions HERMA 400
110/154 3.28 US (130519)
9.8.19 180 Stop signal
Rising edge (stand.):
Web transport is stopped with the rising edge of the label.
Sensor mark:
Web transport is stopped on detection of a sensor mark. Use parameters 131 through 133 for
specifying.
Stop inhibit:
Stop of web transport is inhibited on a distance determined with parameter 134.
Hole inhibit:
For annulus labels the stop of web transport can be inhibited in the hole on a distance determined with
parameter 135.
No label length check:
Normal stop of web transport, however, without teaching the label length, i.e. transport stops with the
next signal or after 800 mm at the latest.
Falling edge:
Web transport is stopped with the falling edge of the label.
9.8.20 181 Stop signal Mark field 1
This parameter will appear only if parameter 180 is set to „01 Sensor mark“. With PWL2 only.
The length of sensor mark field 1 (the distance in front of the actual mark).
9.8.21 182 Stop signal Mark field 2
This parameter will appear only if parameter 180 is set to „01 Sensor mark“. With PWL2 only.
The length of sensor mark field 2 (the distance of the actual mark).
9.8.22 183 Stop signal Mark field 3
This parameter will appear only if parameter 180 is set to „01 Sensor mark“. With PWL2 only.
Optional. The length of sensor mark field 3 (the distance behind the actual mark).
9.8.23 184 Stop inhibit Stop inhibit distance
This parameter will appear only if parameter 180 is set to „02 Stop inhibit“. With PWL2 only.
The distance on which a stop signal is to be inhibited (suppressed) after one stop signal was received.
9.8.24 185 Hole inhibit Hole inhibit distance
This parameter will appear only if parameter 180 is set to „03 Hole inhibit“. With PWL2 only.
The distance of the hole of annulus labels on which a stop signal is to be inhibited (suppressed).
9.8.25 186 Label tolerance
This parameter will appear only after activating the special function of „Quality monitoring“. With
PWL2 only.