9
Operating instructions
HERMA 400 OPERATION (VIA THE HERMA 400 CONTROL)
3.28 US (130519) 111/154
The maximum deviation tolerance with activated quality monitoring. If this tolerance is exceeded
further labeling processes will be stopped and a corresponding error message generated.
See also section „944 Monitoring quality“ on page 123.
9.8.26 187 Stop sensor Label position
Enter here which label the stop sensor (label sensor) is positioned on, where the label directly at the
dispensing beak is number „1“. With PWL2 only.
9.8.27 188 Stop at missing label
With PWL2 only.
Off:
If labels are missing on the web the web is transported further to the next label available (maximum
three times a label length).
On:
If labels are missing on the web the web is stopped as if labels were available.
Coupled with printer:
The function depends on whether a printer is switched on (in which case this function is active) or
switched off (in which case this function is not active).
9.8.28 189 Stop sensor: NoLabel
With PWL2 only.
Enter here when to activate the output NO_LABEL (X19.10).
at sensor (standard):
Activating at the label sensor.
at dispensing beak:
Activating if the missing label „is“ at the dispensing beak.
at disp. beak . +FEED:
Activating if the missing label „is“ at the dispensing beak. Label feed is done automatically.
at disp. beak +FAULT:
Activating if the missing label „is“ at the dispensing beak. Error message SM106, „Missing label at
dispensing beak“ is shown.
9.8.29 190 Printer on/off
Switch the optional printer on or off.
9.8.30 192 Printer Every nth label
With PWL2 only. If parameter 191 (printer mode, available wih PWL3 only) is set to „Standstill, every
nth“.
Indication that only every nth label gets printed onto, with n=1...255.
9.8.31 194 Printer Start delay
With PWL2 only. The time in milliseconds until the printer actually starts printing after the end of web
transport.