5
Technical Data
Operating instructions HERMA 400
76/154 3.28 US (130519)
5.2 Inputs / outputs (X10) (option, standard signals)
This optional connector provides inputs/outputs to the external control (e.g. PLC).
Risk of electric shock! Disconnect all sources of supply and wait for five
minutes before opening the rear cover or touching the connector pins!
Electrocution may occur.
* Note: Put pin to ground, if not used.
Note: Functionality active only if jumper „Remote“ (see wiring diagram) is set.
X10 Designation I/O Description Color
97941
PIN
1Led3 out
LED function key (printer status)
brown
X22.8
2 Gnd i/o Ground (all voltages DC) blue
X22.2
3 Ready out Applicator ready white
X22.4
4 End out End of reel green
X22.7
5 Dim out Diminishing reel pink
X22.5
6
On
in Applicator ON (1-active) yellow
X22.3
7 Fault out Error applicator (incl. web break) black
X22.6
8 Stopdelay* in 0-10V stop delay grey
X23.4
9 Adc+10V out +10V DC for analog inputs red
X23.1
10 Speed* in 0-10V speed violet
X23.3
11 Startdelay* in 0-10V start delay greypink
X23.5
12 Ack in Reset error redblue
X22.1