9
Operation (via the HERMA 400 control)
Operating instructions HERMA 400
114/154 3.28 US (130519)
————————The following parameters will appear only if parameter 201 (available only for
Technical Service) is set to „X17: Pivot beak“.————————
9.9.2 210 Pivot beak on/off
Switch the optional pivot beak on or off.
9.9.3 211 Pivot beak Type
Coupled with label:
The pivot beak is activated in conjunction with the web transport.
Always on:
The pivot beak is always activated (in lower position), if the applicator is switched on and there is no
malfunction.
Product related:
Start delay and activation time of the pivot beak can be adjusted individually (see parameters 212 and
213). The times are dependent on the product detection.
Label related:
Start delay and activation time of the pivot beak can be adjusted individually (see parameters 212 and
214). The times are dependent on start and stop of label transport. Negative values can also be used,
which means that in such case the pivot beak can be lowered before label transport starts and can be
moved upwards before label transport stops.
9.9.4 212 Pivot beak Start delay
This parameter will appear only if parameter 211 is set to „Product related“ or „Label related“.
If parameter 211 is set to „Product related“ this start delay indicates the distance in mm the product
covers after detection until the pivot beak is activated.
If parameter 211 is set to „Label related“ this start delay indicates the distance in mm the web is
transported until the pivot beak is activated. Note: This parameter can also take a negative value
(max. the value of the quick menu’s parameter set for the start delay of the label) and will in such case
effect that the pivot beak is activated before the label transport.
9.9.5 213 Pivot beak Activation time
This parameter will appear only if parameter 211 is set to „Product related“.
The distance in mm (in relation to the web transport distance) within which the pivot beak remains
activated after starting.
9.9.6 214 Pivot beak Stop delay
This parameter will appear only if parameter 211 is set to „Label related“.
The delay (distance in mm covered, in relation to the web transport distance) after which the pivot
beak is deactivated after the stop of the web transport. Note: This parameter can also take a negative
value and will in such case effect that the pivot beak is deactivated already before the end of the label
transport.
——————————End of parameters for pivot beak—————————