Operating instructions
HERMA 400 OPERATION (VIA THE HERMA 400 CONTROL)
3.28 US (130519) 129/154
07 100% (O):
08 90% (S):
09 90% (T):
10 90% (O):
11 70% (S):
12 70% (T):
13 70% (O):
14 60% (S): Soft
15 60% (T):
9.12.23 958 Unwinder protection 1
With PWL2 only. With the help of this parameter the sensitivity of the unwinder protection can be set
via movement of the pendulum. Normally the pendulum will never remain in the same position within
a certain distance but will swing around its working point. This fact is used here. If the pendulum
remains in the same position over a long distance you may suspect the pendulum is blocked. An error
message is generated.
The following settings for the sensitivity are available:
00 Off: Switched off.
01 Tolerant: A longer unwinding distance is possible.
02 Normal: .
03 Strict: Short unwinding distance.
The parameter may have to be adapted to the production conditions.
9.12.24 959 Unwinder protection 2
With PWL2 only. With the help of this parameter the sensitivity of the unwinder protection can be set
via the removal / unwinding distance. It is an indication that if the unwinding distance is much higher
than the feeding distance of the applicator there is a malfunction of the unwinder.
The following settings for the sensitivity are available:
00 Off: Switched off.
01 Tolerant: A longer unwinding distance is possible.
02 Normal: .
03 Strict: Short unwinding distance.
The parameter may have to be adapted to the production conditions.
Monitoring mus be swltched off if e. g. a printer loop is built from an autonomous printing unit . Here
label feed is asynchronous to unwinding.
9.12.25 990 Bus adress (RS485)
With PWL2 only.
The address of the applicator if integrated in a network via RS485.
If possible, the following address defaults should be adhered to: