10 Cleaning, maintenance, service
Working on the applicator for cleaning or maintenance while it is
connected to mains this could lead to unintended connection to electric
current. Before carrying out cleaning or maintenance work disconnect
applicator / machine from mains! Otherwise this could lead to serious
njuries.
Set the applicator to standyby mode ( is off) before changing the label
roll.
Cleaning notes
Use cleaning material only that does not attack metal, rubber, or plastics
parts.
Make sure that all machine parts that touch the products to be labeled are
free from adhesive or label fragments.
Remove adhesive residue with a label solvent.
Clean label sensing/scanning unit with a soft cloth only.
Do not remove adhesive residue from reversing and feed rollers with sharp-
edged objects.
Some more notes on cleaning you will find in the respective description of the sub-assemblies
(sections 4.1).
Exchanging fuses
Risk of electric shock! Disconnect all sources of supply and wait for five
minutes before opening the rear cover or touching the connector pins!
Electrocution may occur.
> Use suitable gripping tool for removing and inserting.
See chapter 5 for fuse specifications.
Important: Opening the screws at the front of the drive unit
HERMA 400 will
void the warranty!