9
Operating instructions
HERMA 400 OPERATION (VIA THE HERMA 400 CONTROL)
3.28 US (130519) 117/154
————————The following parameters will appear only if parameter 201 (available only for
Technical Service) is set to „CAN: Type 152“.————————
9.9.18 260 Prism control system
Standard:
The prism is activated after product recognition and a configurable start delay (parameter 263). Upon
expiry of the start delay in the quick menu, the labeling process is started. After the labeling cycle has
finished, the prism is opened following a configurable stop delay (parameter 264).
Fix: start monitoring:
This operating mode is intended for aligned labeling, where the products always exit the prism at the
same interval.
The prism is activated after product recognition and a configurable start delay (parameter 263).
Following a configurable start delay (parameter 265), the actual product recognition starts, e.g. the
detection of a sensor mark. At the same, the activation time for the prism is started.
If no product is detected within the configurable start monitoring time (parameter 266), the start
trigger is blocked and the prism opened again after the set activation time.
Fix: start mon. + Err:
As above, except that the machine is stopped and an error message issued if the synchronisation mark
(e.g. sensor mark) is not detected.
Fix: start mon. + Err+Dir:
As above, except that the activation time depends on the start of the labeling process. As a result,
the
products leave the prism station aligned by the label position.
9.9.19 261 Outfeed jam Running time
The sensor for detecting an outfeed jam must remain covered for the period specified here in order for
a jam to be recognised.
9.9.20 262 AUTOMATIC Slow-down time
Specification of how long the machine continues to run (in order to run empty) after deactivation
(pressing of the “Automatic” button).
9.9.21 263 Prism Start delay
Delay between product recognition and closing of the roller prism in order to securely grasp the
product.
9.9.22 264 Prism Stop delay
Delay between successful labeling and opening of the roller prism to ensure that the label is fully
applied.
9.9.23 265 Start detection Start delay
In the case of positioned labeling (aligned according to a sensor mark), this is the time between
activation of the prism and start of the sensor mark search.
9.9.24 266 Start detection Start monitoring
Time limit for parameter 265 (to avoid an endless search if the sensor mark cannot be detected).