Operation (via the HERMA 400 control)
Operating instructions HERMA 400
116/154 3.28 US (130519)
————————The following parameters will appear only if parameter 201 (available only for
Technical Service) is set to options with moving beak and/or transfer unit and/or Blow box, e.g. to
„CAN: Mov. beak + tel.“ (moving beak + telescope (transfer unit)).————————
9.9.9 225 Dispensing unit Label start delay
The delay as of starting the moving beak until the label transport is activated. For optimising the
labeling process you may for certain applications want to start the label transport even before the
beak reaches its operational position. The dispensing beak, however, must have reached its working
position before label transport is completed!
9.9.10 226 Dispensing unit Work pos. reached
Only if application type 201 is set to „11 CAN: Beak + mov. tel.“.
The time until the unit is in its working position. This sub-assembly is connected to output X17.2.
9.9.11 227 Dispensing unit Work pos. return del.
The time the beak remains activated before it is switched off (return movement started). A little delay
may be required to allow any take-up cylinder (short-stroke cylinder at the transfer unit) to complete
its cycle. This component would be connected to output X17.2.
9.9.12 229 Dispensing unit Home pos. reached
The time the beak is given to reach its home position. If a end of travel sensor ls available this is the
maximum time before an error message would be displayed.
9.9.13 235 Transfer unit After blow
For application type „Blow box“: The time required until, after blowing, the unit is ready for the next
cycle.
9.9.14 236 Transfer unit Work pos. reached
The time the transfer unit is given to reach its operational position. If a end of travel sensor ls available
this is the maximum time before an error message would be displayed.
9.9.15 237 Transfer unit Work pos. return del.
The time the transfer unit remains activated before it is switched off (return movement started). A
little delay may be required to make sure label transfer is troublefree, or to have sufficient time for any
blowing.
9.9.16 238 Transfer unit Blow
The time available for blowing. This time starts at the same time as the delay time in parameter 237.
9.9.17 239 Transfer unit Home pos. reached
For application types except „Blow box“: The time the transfer unit is given to reach its home position.
If a end of travel sensor ls available this is the maximum time before an error message would be
displayed.
——————————End of parameters for moving beak and/or telescope—————————