Parameter 952 with 05 Fix: **********, parameter 953 with 01 100%.
For small label feeds at moderate speed and sensitive label web this parameter setting may deliver
good results:
Parameter 952 with 09 Fix: ******, parameter 953 with 06 75%.
9.12.19 954 Unwinder Mode
With PWL2 only. This parameter determines the operational behaviour of the unwinder.
00 Normal: Integrated in production mode.
01 Passive: All functions available, but status or output of error messages will not be transmitted.
02 Off: No functions.
9.12.20 955 Rewinder Mode
With PWL2 only. This parameter determines the operational behaviour of the rewinder.
00 Normal: Integrated in production mode.
01 Passive: All functions available, but status or output of error messages will not be transmitted.
02 Off: No functions.
9.12.21 956 Loop unwinder Mode
With PWL2 only. This parameter determines the operational behaviour of the loop unwinder.
00 Normal: Integrated in production mode.
01 Passive: All functions available, but status or output of error messages will not be transmitted.
02 Off: No functions.
9.12.22 957 Rewinder output
With PWL2 only.
For optimizing the rewinder‘s behavior this parameter affects the rewinder‘s characeristics as well as
the stop delay in case of a web break. In this context the information on the stop delay means:
(S) Sensitive (short delay)
(T) Tolerant (long delay)
(O) Off (an error mesage will not be generated).
00 Standard (S):
01 Standard (O):
02 Automatik (S): Automatically adapted to the labeling speed.
03 Automatik (T): Automatically adapted to the labeling speed.
04 Automatik (O):
05 100% (S): Aggressive.
06 100% (T):