4 Individual remote controls
PC-ARF
TCGB0106 rev.0 - 12/2014
113
4
Defrost
Defrost Operation
“DFR” is turned ON during the defrosting.
The indoor fan is stopped though the indication is not changed. The louver is
xed at the horizontal position. However, the louver indication of LCD continues
to activate.
A/C
LOUV. ADJ
DFR
Turned ON
MODE SPEED LOUV.
HEAT
MED
TEMP
Meeting Room
Operation Stoppage during Defrosting Operation
The RUN indicator (Green) is turned OFF when the operation is stopped during the defrosting.
However, the operation continues with “DFR” indication, and the unit is stopped after the defrost operation is nished.
Operation control
Supplying Electrical Power
“HOT-ST” is turned ON when the electrical power is turned ON.
In this case, the compressor is under preheating. The operation may not be
available for max 4 hours. Do not turn off the outdoor unit electrical power during
the high season for Cooling/Heating operation.
A/C
HOT-ST
LOUV. ADJ
Turned ON
MODE SPEED
HEAT
MED
TEMP
Meeting Room
During Hot Start (Heating Operation Only) “HOT-ST” is turned ON.
A/C
LOUV.
HOT-ST
LOUV. ADJ
Turned ON
MODE SPEED
HEAT
MED
TEMP
Meeting Room
Different Operation Mode
The operation mode set by the remote control switch is different with the out-
door unit operation mode. (Except for the heat recovery system models.)
The indication of the actual operation mode ashes.
Indication when “COOL” operation is set by the remote control switch at the
outdoor unit “HEAT” operation.
A/C
HEAT
LOUV.
LOUV. ADJ
COOL
MED
TEMPMODE SPEED
Flashing
Meeting Room

Table of Contents

Other manuals for Hitachi PSC-A1T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi PSC-A1T and is the answer not in the manual?

Hitachi PSC-A1T Specifications

General IconGeneral
BrandHitachi
ModelPSC-A1T
CategoryController
LanguageEnglish

Related product manuals