Main parameters setting
Operation Mode
1 Select the target group at screen of “Monitor 1 (All Groups)” or “Monitor 2 (Block)” to change the operation mode set-
ting. The pop-up of “Setting” for the selected group is displayed on the touchscreen.
Monitor 1 (All Groups) Monitor 2 (Block)
Monitor 1 (All Groups)
Menu
25/01/2010 (Mon) 10:20
F-Level
1-B
F-Level
1-A
F-Level
2
Annex
Group1A-01
Group1A-03
Group1A-05
Group1A-07
Group1A-09
Group1A-11
Group1A-13
Group1A-15
Group1A-02
Group1A-04
Group1A-06
Group1A-08
Group1A-10
Group1A-12
Group1A-14
Buffet 1
North Area
Buffet 1
South Area
Buffet 1
East Area
Buffet 1
West Area
Buffet 2
North Area
Buffet 2
South Area
Buffet 2
East Area
Buffet 2
West Area
Meeting
Room A
Meeting
Room B
Meeting
Room C
Meeting
Room E
Meeting
Room D
Kiosk
Group1A-16
Group1B-03
Group1B-05
Group1B-07
Group1B-09
Group1B-11
Group1B-13
Group1B-02Group1B-01
Group1B-04
Group1B-06
Group1B-08
Group1B-10
Group1B-12
Group2-01
Group2-03
Group2-05
Group2-07
Group2-09
Group2-11
Group2-02
Group2-04
Group2-06
Group2-08
Group2-10
All Groups
Setting
All Groups
Run
All Groups
Stop
(1)
Menu
25/01/2010 (Mon) 10:20
Monitor 2 (Block)
Setting by
Block
Run by
Block
Stop by
Block
26
DRY LOW
Group1A-01
All Groups Annex
F-Level
1-A
F-Level
1-B
F-Level
2
24
DRY LOW
Group1A-05
20
DRY LOW
Group1A-09
22
DRY LOW
Group1A-13
26
DRY LOW
Group1A-02
24
DRY LOW
Group1A-06
20
DRY LOW
Group1A-10
20
DRY LOW
Group1A-14
20
DRY LOW
Group1A-03
26
DRY LOW
Group1A-07
26
DRY LOW
Group1A-11
19
DRY LOW
Group1A-15
25
DRY LOW
Group1A-04
26
DRY LOW
Group1A-08
23
DRY LOW
Group1A-12
22
DRY LOW
Group1A-16
AUTO
AUTO
AUTO
AUTO
(1)
2 By tapping “ ” or “ ” of the “OPE. MODE”, the operation mode will be changed alternately as follows.
COOL
HEAT
DRY
FAN
The “AUTO” (Heating/Cooling Automatic Operation) will be included as option if applicable.
3 Tap “Close” to return to the screen of “Monitor 1 (All Groups)” or “Monitor 2 (Block)”.
Close
26
DRY LOW
RUN
STOP
F-Level 1-A
Group1A-02
AUTO
Setting
Operation
Setting
RCS Operation
Prohibited
RUN/STOP OPE. MODE
FAN SPEED
LOUVER SET TEMP.
(2)
(3)
NOTE
In the case of “Run/Stop Only” mode, setting change is available by only “All Groups Setting” or “Setting by Block” button. (Setting
change for each group is NOT available).
Some operation modes cannot be set depending on the unit model. Contact your dealer for detailed information.
5 Centralised remote controls
PSC-A64GT
TCGB0106 rev.0 - 12/2014
245
5

Table of Contents

Other manuals for Hitachi PSC-A1T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi PSC-A1T and is the answer not in the manual?

Hitachi PSC-A1T Specifications

General IconGeneral
CategoryController
TypeProgrammable Logic Controller
Input Voltage100-240 VAC
Frequency50/60 Hz
Operating Temperature0°C to 55°C
Storage Temperature-20°C to 70°C

Related product manuals