135
Interface bandwidth Cost
≤622 Mbps 30
≤2500 Mbps 20
>2500 Mbps 10
Examples
# Enable automatic link cost calculation for IS-IS process 1.
<Sysname> system-view
[Sysname] isis 1
[Sysname-isis-1] auto-cost enable
Related commands
• bandwidth-reference
• cost-style
bandwidth-reference (IS-IS view)
Use bandwidth-reference to set the bandwidth reference value for automatic link cost calculation.
Use undo bandwidth-reference to restore the default.
Syntax
bandwidth-reference value
undo bandwidth-reference
Default
The bandwidth reference value is 100 Mbps.
Views
IS-IS view
Predefined user roles
network-admin
Parameters
value: Specifies the bandwidth reference value in the range of 1 to 2147483648 Mbps.
Examples
# Configure the bandwidth reference of IS-IS process 1 as 200 Mbps.
<Sysname> system-view
[Sysname] isis 1
[Sysname-isis-1] bandwidth-reference 200
Related commands
auto-cost enable
circuit-cost
Use circuit-cost to set a global IS-IS link cost.