Combining the Sweep Mode With the Sweep Generation Command
to Obtain the Desired Sweep Condition
Description of
Sweep Condition
CW
Non-swept
Analog
freq
sweep
Manual analog
freq
sweep
Stepped freq sweep
Manual step
freq
sweep
CW with analog power
sweep
CW with manual analog
power sweep
CW with stepped power
sweep
CW with manual stepped
power sweep
Analog frequency and
power sweep
Manual analog frequency
and power sweep
Stepped frequency and
power sweep
Manual stepped frequency
and power sweep
List sweep
Manual list sweep
FREQ
:POW
:MODE :MODE
cw FIX
SWE FIX
SWE FIX
SWE
FIX
SWE
FIX
cw SWE
cw SWE
cw
SWE
cw SWE
SWE
SWE
SWE SWE
SWE SWE
SWE SWE
LIST
ignored
LIST
ignored
SWE :LIST
:MODE
:MODE
ignored
ignored
AUTO
ignored
MAN
ignored
AUTO
ignored
MAN
ignored
AUTO
ignored
MAN
ignored
AUTO
ignored
MAN
ignored
AUTO
ignored
MAN
ignored
AUTO
ignored
MAN
ignored
ignored
AUTO
ignored
MAN
SWE
:GEN
ignored
ANAL
ANAL
STEP
STEP
ANAL
ANAL
STEP
STEP
ANAL
ANAL
STEP
STEP
ignored
ignored
l
SWEep:GENeration
STEPpedlANALog
l
SWEep:GENeration?
Sets and queries the type of sweep to be generated: an analog sweep
or a digitally stepped sweep. In either case, all of the other sweep
subsystem functions apply. *RST is
ANALog.
l
SWEep:MANual:POINt
<num>lMAXimumlMINimum
l
SWEep:MANual:POINt?
[MAXimumlMINimuml
Sets and queries the step point number to go to and lock. The value
is a
unitless
value that is limited between 1 and the number of points
requested. This command has no effect on the instrument unless:
the sweep mode is set to manual and the sweep generation is set to
stepped mode.
*RST value is 1.
l
SWEep:MANual[:RELative]
<num>
l
SWEep:MANual[:RELative]?
Sets and queries a percent of sweep to go to and lock. This command
has no effect unless: the sweep mode is set to manual and the sweep
generation is set to analog.
*RST
value is 0.50.
S-50 Operating and Programming Reference