Step Sup
Menu
Step
Swp
Menu
Function Group
FREQUENCY
Menu Map
2
Description
This softkey reveals the stepped
frequency
sweep entry menu.
Dwell Coupled
Step Control Master
Step Control Slave
Step Dwell
Step Points
Step Size
Step
Sup
Pt Trig Auto
Step
Sup
Pt Trig Bus
Step
Sup
Pt Trig Ext
Programming Codes
SCPI: NONE
Analyzer: NONE
Couples the dwell time for stepped
sweep points to ramp sweep, sweep
time.
Causes the swept signal generator
to act as the master control in
a dual swept signal generator
measurement setup.
Causes the swept signal generator
to act as the slave in a dual swept
signal generator measurement
setup.
Sets the dwell time for points in
stepped sweep.
Sets the number of points in a
stepped sweep.
Sets the increment value for the
points in a stepped sweep.
Automatically steps the swept
signal generator to the next point in
a stepped sweep.
Steps the swept signal generator to
the next point in a stepped sweep
when an HP-IB trigger is received.
Steps the swept signal generator to
the next point in a stepped sweep
when an external hardware trigger
is received.
See Also
[K),
(m),
Sweep Mode Step , [SWEEP TIME)
“Using Step Sweep” in Chapter 1