10
MHz
Freq
Std
Extrnl
Function Group
SYSTEM
Menu Map
8
Description
This softkey tells the swept signal generator to accept an external
10 MHz signal as the frequency reference. The external signal must
be applied to the 10 MHz REF INPUT BNC connector located on
the rear panel. If no external signal is applied, UNLOCK and EXT REF
appears on the message line of the display. An asterisk next to the
key label indicates that this feature is active.
Programming Codes
SCPI: ROSCillator[:SOURce]
EXTernal
Analyzer: NONE
See Also
Ref
Osc
Menu
10
MHz
Freq
Std
Intrnl
Function Group
Menu Map
Description
Programming Codes
See Also
SYSTEM
8
This softkey sets the swept signal generator to select the internal
10 MHz signal as the frequency reference. If the internal signal
is disconnected or not working properly, UNLOCK appears on the
message line of the display. An asterisk next to the key label
indicates that this feature is active.
SCPI: ROSCillator[:SOURce]
INTernal
Analyzer: NONE
Ref Osc Menu
T-2 Operating and Programming Reference