3. Record the DC SAN Director values on a workstation.
a. Record the WWN value: Type wwn, then copy the command output into a file named
config-miscinfo.txt.
rsl8-st03-dcx-1:admin> wwn
10:00:00:60:69:00:00:0a
b. Record the IP address information.
Type ipAddrShow -sw, then copy the command output into the config-miscinfo.txt
file.
rsl8-st03-dcx-1:admin> ipAddrShow —sw
SWITCH
Ethernet IP Address: 10.32.50.12
Ethernet Subnetmask: 255.55.0.0
Fibre Channel IP Address: 1.2.3.4
Fibre Channel Subnetmask: 255.255.255.0
CP0
Ethernet IP Address: 10.32.50.10
Ethernet Subnetmask: 255.55.0.0
HostName : cp0
Gateway Address: 10.32.40.1
CP1
Ethernet IP Address: 10.32.50.11
Ethernet Subnetmask: 255.55.0.0
HostName : cp1
Gateway Address: 10.32.40.1
Backplane IP address of CP0 : 10.0.0.6
Backplane IP address of CP1 : 10.0.0.7
rsl8-st03-dcx-1:admin>rsl8-st03-dcx-1:admin
c. Display and record the manufacturer serial numbers.
Type chassisShow, then copy the command output into the config-miscinfo.txt file.
“Factory Serial Num” and “Serial Num” are listed under “Chassis/WWN Unit 1.” If the
current WWN cards are the original cards, the factory serial number listed is the same as
the chassis serial number.
rsl8-st03-dcx-1:admin> chassisshow
Chassis Backplane Revision: 1F
SW BLADE Slot: 1
Header Version: 2
Power Consume Factor: -50
Factory Part Num: 60-0001532-03
Factory Serial Num: KP000000195
Manufacture: Day: 1 Month: 1 Year: 2007
Update: Day: 14 Month: 3 Year: 2012
Time Alive: 187 days
Time Awake: 3 days
<output truncated>
Replacing DC SAN Director field-replaceable units (FRUs)100