2. Check the blower assembly status using the fanShow command.
The status for each blower assembly displays OK, Absent, or Faulty. The RPM of each fan in the
assembly is also provided. If a blower assembly is absent or faulty, contact HP.
Figure 61 Blower assembly
2. Fault LED1. Power LED
Table 34 Blower assembly LED descriptions
Recommended actionStatusColorLED
pur-
pose
Ensure that the blower assembly is
firmly seated and has power.
Blower assembly does not
have incoming power.
No light (LED is off)Power
No action requiredBlower assembly has incoming
power.
Steady green
Ensure that the blower assembly
has incoming power.
Blower assembly is either
healthy or does not have in-
coming power.
No light (LED is off)Fault
Replace blower assembly.Blower assembly has a failure
(full or partial).
Steady amber
Pull unit out and reseat. If LED con-
tinues to flash, replace unit.
Blower assembly is not seated
correctly or is faulty.
Slow-flashing amber (on
2 sec, then off 2 sec)
Monitoring DC04 SAN Director system components166

Table of Contents

Other manuals for HP A7533A - Brocade 4Gb SAN Switch Base

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP A7533A - Brocade 4Gb SAN Switch Base and is the answer not in the manual?

HP A7533A - Brocade 4Gb SAN Switch Base Specifications

General IconGeneral
BrandHP
ModelA7533A - Brocade 4Gb SAN Switch Base
CategorySwitch
LanguageEnglish

Related product manuals