PoE Port Configuration 105
Modifying Port PoE Settings
To change PoE settings for a port, select the checkbox associated with it and click Edit.
Figure 73. Edit PoE Port Configuration Page
To configure the same settings for all PoE-enabled ports, click Edit All.
Click Apply to save any changes for the current boot session. The changes take effect immediately but
are not retained across a switch reset unless you click Save Configuration.
Power Detect Type The PD detection mechanism performed by the PSE port. Possible value are:
Dot3af/atThe 4-point detection scheme defined in IEEE 802.3af is used. This is the
default option.
Dot3af/at + Pre-StandardThe 4-point detection scheme defined in IEEE 802.3af is
used. If this mechanism fails to detect a connected PD, Dot3af/at detection is used.
Power Limit Type The type of power limiting used for the port. Possible values are:
Class—The device class determines the power limit. The switch learns the class of the
device through the receipt of LLDP messages. This is the default selection.
User—The power limit is user-defined, overriding the LLDP information.
When set to User, the specified power limit also displays next to this value. When High Power
Mode is enabled, the maximum value is 30W. When High Power Mode is disabled, the
maximum value is 15.4W. (The Power Limit field is available on the Edit PoE Port
Configuration page.)
Status The status of the port as a provider of power over Ethernet. Such devices are referred to as
power-sourcing equipment (PSE). Possible values are:
Disabled—The PSE is disabled.
Delivering Power—The PSE is delivering power.
Fault—The PSE has experienced a fault condition.
Test—The PSE is in test mode.
Other Fault—The PSE has experienced a variable error condition.
Searching—The PSE is transitioning between states.
Requesting Power—The PSE is currently not able to deliver power because power is
unavailable to the port.
Fault Status The fault status, if a fault occurred. Possible values are:
NoneNo faults have occurred.
ShortThe switch provided insufficient current to a connected PD
OverloadA connected PD has attempted to draw more than the allowed watts.
Power DeniedA PD requesting power on the port has been denied because of insuffi-
cient power available.
Field Description

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HPE OfficeConnect 1920S8G series and is the answer not in the manual?

HPE OfficeConnect 1920S8G series Specifications

General IconGeneral
BrandHPE
ModelOfficeConnect 1920S8G series
CategorySwitch
LanguageEnglish

Related product manuals