208 Powermax125 Service Manual 808070
9 Power Supply Component Replacement
Figure 75 400 V CE / 380 V CCC power board
J6 J5
J3 J2 J1
RED
J18
ORG
J17
RED
J32
J11
B
R
J27
WORK
LEAD
J26
C152 C151
J25
+
_
+
_
J28
TP7
TP9
TP8
W
R
B
1
2
4
5
6
7
8
9
12
17
10
1
8
3
11
3 13
14
15
3
16
33 3
1 Gate drive connectors
2 J11
3 Board mounting screws (7)
4 J17
5 J18
6 Output inductor wires
7 Nozzle wires
8 Electrode wire
9 J32
10 Work lead
11 Transformer wires
12 4 μF capacitors
13 Capacitor screws (4)
14 PFC inductor wires
15 Input diode bridge screws (5)
16 AC input wires (3)
17 Transformer mounting screws
18 J6, J5, J3, J2, and J1

Table of Contents

Other manuals for Hypertherm Powermax 125

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax 125 and is the answer not in the manual?

Hypertherm Powermax 125 Specifications

General IconGeneral
Output Current30-125 A
Input Power15.2 kW
Open Circuit Voltage300 VDC
Gas SupplyClean, dry, oil-free air or nitrogen
Input Power Cable Length10 ft (3 m)
Rated Output Current125 A
Gas TypeAir or nitrogen
Cutting Capacity1-1/4 inch (32 mm)
Pierce Capacity1 inch (25 mm)
Input Voltage200-600 V, 3-PH
Duty Cycle100% @ 125 A
CertificationsCSA
Maximum Clean Cut Thickness1-1/4 inch (32 mm)
Cooling MethodFan-cooled
Torch OptionsHand