EasyManuals Logo

IBM V7000 User Manual

IBM V7000
670 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #359 background imageLoading...
Page #359 background image
Chapter 8. Storage pools 339
Choose the storage pool to which you want to add the MDisk and click Add to Pool
(Figure 8-29).
Figure 8-29 Add MDisk to Pool
After IBM Flex System V7000 Storage Node completes this action, the MDisk shows up in the
pool that it was added to (Figure 8-30).
Figure 8-30 MDisk added to pool
Existing data: If there is existing data on the unmanaged MDisks that you need to
preserve, do
not select Add to Pool on this LUN, as this action deletes the data.
Use Import instead, which is described in 8.2.2, “Importing MDisks” on page 342.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM V7000 and is the answer not in the manual?

IBM V7000 Specifications

General IconGeneral
ModelIBM Storwize V7000
Storage TypeHybrid Flash Array
Maximum Capacity1.2PB
RAID Levels0, 1, 5, 6, 10
Connectivity8 Gbps Fibre Channel, 16 Gbps Fibre Channel, 1 Gbps iSCSI, 10 Gbps iSCSI
ManagementCommand-line interface (CLI), Graphical user interface (GUI)
Form Factor2U
Drive Bays12
Maximum Raw Capacity1.2PB
Operating System SupportAIX, HP-UX, Linux, VMware, Windows
Data Reduction FeaturesReal-time Compression, Deduplication
Drive TypesSSD, HDD
ScalabilityScale-up (drive enclosures) and scale-out (clustering) capabilities

Related product manuals