Chapter 12. Host configuration 559
Using SDDPCM
The SDDPCM is administered using the pcmpath command. This commands is used to
perform all administrative functions such as displaying and changing the path state.
The pcmpath query adapter command displays the current state of the adapters. In
Example 12-14, we can see the adapter status and that both adapters are showing as optimal
with State=NORMAL and Mode=ACTIVE.
Example 12-14 SDDPCM commands that are used to check the availability of the adapters
# pcmpath query adapter
Total Dual Active and Active/Asymmetric Adapters : 2
Adpt# Name State Mode Select Errors Paths Active
0 fscsi0 NORMAL ACTIVE 949 0 4 4
1 fscsi1 NORMAL ACTIVE 991 0 4 4
The pcmpath query device command displays the current state of the volume devices and
their paths. In Example 12-15, we can see the path State and Mode for each of the defined
hdisks. The status that both adapters are showing as optimal with State=OPEN and
Mode=NORMAL.
Additionally, an asterisk (*) displayed next to paths indicates inactive paths that are configured
to the non-preferred IBM Flex System V7000 Storage Node canisters in the I/O Group.
Example 12-15 SDDPCM commands that are used to check the availability of the devices
# pcmpath query device
Total Dual Active and Active/Asymmetric Devices : 2
DEV#: 1 DEVICE NAME: hdisk1 TYPE: 2145 ALGORITHM: Load Balance
SERIAL: 60050760008F0006F800000000000029
==========================================================================
Path# Adapter/Path Name State Mode Select Errors
0 fscsi0/path0 OPEN NORMAL 574 0
1* fscsi0/path1 OPEN NORMAL 42 0
2 fscsi1/path2 OPEN NORMAL 633 0
3* fscsi1/path3 OPEN NORMAL 42 0
DEV#: 2 DEVICE NAME: hdisk2 TYPE: 2145 ALGORITHM: Load Balance
SERIAL: 60050760008F0006F80000000000002A
==========================================================================
Path# Adapter/Path Name State Mode Select Errors
0* fscsi0/path0 OPEN NORMAL 42 0
1 fscsi0/path1 OPEN NORMAL 293 0
2* fscsi1/path2 OPEN NORMAL 42 0
3 fscsi1/path3 OPEN NORMAL 276 0
#

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM V7000 and is the answer not in the manual?

IBM V7000 Specifications

General IconGeneral
ModelIBM Storwize V7000
Storage TypeHybrid Flash Array
Maximum Capacity1.2PB
RAID Levels0, 1, 5, 6, 10
Connectivity8 Gbps Fibre Channel, 16 Gbps Fibre Channel, 1 Gbps iSCSI, 10 Gbps iSCSI
ManagementCommand-line interface (CLI), Graphical user interface (GUI)
Form Factor2U
Drive Bays12
Maximum Raw Capacity1.2PB
Operating System SupportAIX, HP-UX, Linux, VMware, Windows
Data Reduction FeaturesReal-time Compression, Deduplication
Drive TypesSSD, HDD
ScalabilityScale-up (drive enclosures) and scale-out (clustering) capabilities

Related product manuals