WindO/I-NV4 Users Manual 28-27
3 FTP Client Function
28
Maintenance
Destination
Select the target external memory device or the FTP server where the files to be copied or moved are stored from the
following items.
SD Memory Card
*1
, USB Flash Drive, (FTP server)
The No.+.(period)+Server Name of the FTP server specified in the FTP Server Manager is displayed.
Example: No. is 1 and Server Name is TestServer1
1.TestServer1
Operation
Selects Copy or Move for the procedure to transfer the files. Can only be set Copy when Source is set to (FTP
server).
*1 HG5G/4G/3G/2G-V, HG4G/3G, HG2G-5F only
Location: Selects the method to specify the target save location of files to copy or move.
Fixed: Specify the save location of the target folder path as a string. The maximum number is 247
characters.
Example: Save the copied or moved files to the “ALARMLOG” folder under “HGDATA01” folder
on the external memory device
HGDATA01\ALARMLOG
Click on the External Memory Device Folder button or click on to the right on it, and then
select the item on the list.
Specify the Location by Value of Device Address:
Specifies a word device to specify a folder path of the copied or moved files. The path is set by
reading the values sequentially from the starting device specified and handling those values as
character data up to the character before NULL (0x00). The maximum number of device
addresses is 124 (2 characters per word device, maximum of 247 singlebyte characters). Click
to display the Tag Editor. For the device address configuration procedure, refer to Chapter 2
“5.1 Device Address Settings” on page 2-68.
Files cannot be copied or moved from the FTP server to the FTP server.
When transferring files from external memory to external memory and HMI special internal relay LSM67 is
0, subfolders can be copied and moved up to five folders deep. When HMI special internal relay LSM67 is
changed from 0 to 1, subfolders cannot be copied or moved.
The following single-byte characters cannot be used in the folder or file path configured by Fixed or
Specify the Location by Value of Device Address.
; : * ? " < > |
Folder or File path that exceed the limits in Specify the Location by Value of Device Address and
folder or file path configured with characters that cannot be used are as follows.
- When the text of the folder or file path exceeds the maximum number of device addresses (no NULL),
the text stored in device addresses up to the maximum number of device addresses from the start is
configured.
- When a character that cannot be used is set, the text is up to that character.
If the transfer destination is a MICRO/I configured as an FTP server, “A\” or “B\” must be specified at the
beginning of the path for each type of external memory.
Example 1: If the transfer destination is the “ALARMLOG” folder in the “HGDATA01” folder on the SD
memory card:
A\HGDATA01\ALARMLOG
Example 2: If the transfer destination is the “ALARMLOG” folder in the “HGDATA01” folder on the USB
flash drive:
B\HGDATA01\ALARMLOG
If the destination file exists: Selects Skip or Overwrite for the processing method when there is the same file
name in the destination.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEC MICRO/I HG1P-ST32 Series and is the answer not in the manual?

IDEC MICRO/I HG1P-ST32 Series Specifications

General IconGeneral
BrandIDEC
ModelMICRO/I HG1P-ST32 Series
CategoryControl Panel
LanguageEnglish

Related product manuals