2 USB Autorun Function
31-30 WindO/I-NV4 User’s Manual
command = PRO_DOWNLOAD
src_path (required)
Specify the path (250 or less characters) where the project file is to be downloaded.
Use “A:\” for an SD memory card and “B:\” for a USB flash drive.
reset_keep_device
Specify whether to initialize the keep devices or not when the project file is downloaded. However, when project data
that changes the settings of the data storage area is downloaded, the keep devices are always initialized.
command = PRO_UPLOAD
dst_path (required)
Specify the path to the folder (250 or less characters) where the uploaded project will be saved.
Use “A:\” for an SD memory card and “B:\” for a USB flash drive.
command = LDR_DOWNLOAD
src_path (required)
Specify the path (250 or less characters) where the ZLD Project File is to be downloaded.
Use “A:\” for an SD memory card and “B:\” for a USB flash drive.
dst_port (required)
Specify the name of the MICRO/I port to which the PLC to download from is connected. For details about the port
name, refer to Chapter 4 “Interface Configuration” on page 4-35.
dst_net_no (required when specifying the destination as a slave number or External Device ID)
If the communication interface that connects the PLC for downloading is the serial interface, specify the slave number.
If the communication interface is the Ethernet interface, specify the External Device ID. Specify the same number set
as the slave number or External Device ID for the PLC.
dst_plc_ip (required when specifying the destination as an IP address)
Specify the IP address of the download destination PLC.
Example: dst_plc_ip = 192.168.0.1
Enable: Initializes the keep devices.
Disable: Does not initialize the keep devices.
If you download the project data, Alarm Log data, Operation Log data, and Data Log data is erased
regardless of the reset_keep_device.
If this item is left blank or contains an illegal value, the MICRO/I assumes "Enable".
COM1: The name of the serial interface varies based on the model.
HG5G/4G/3G/2G-V, HG4G/3G, HG2G-5F: COM1
HG2G-5T: SERIAL1(RS232C)
HG1G: COM(RS232C)
COM2: The name of the serial interface varies based on the model.
HG5G/4G/3G/2G-V: COM2(RS232C) or COM2(RS422/485)
HG4G/3G, HG2G-5F: COM2
HG2G-5T: SERIAL1(RS422/485)
HG1G/1P: COM(RS422/485)
ETHER: Ethernet interface (LAN)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEC MICRO/I HG1P-ST32 Series and is the answer not in the manual?

IDEC MICRO/I HG1P-ST32 Series Specifications

General IconGeneral
BrandIDEC
ModelMICRO/I HG1P-ST32 Series
CategoryControl Panel
LanguageEnglish

Related product manuals