- 111 -
IS810N-INT Series Servo System User Manual (Brief)Chapter 4 Wiring
4.7 RJ45 Communication Connection
RJ45 communication interfaces (RJ45A/RJ45B):
RJ45 
communication 
interfaces  
(RJ45A/RJ45B)
CANH
CAN_H of CANopen/CANlink 
communication signal
CANopen/CANlink 
communication 
protocol supported.
CANL
CAN_L of CANopen/CANlink 
communication signal
CGND
Ground of CANopen/CANlink 
communication signal
RS485+
Positive of RS485 
communication signal
Used for RS485 
internal bus, external 
keypad, and PC 
commissioning 
(INoDriveShop)
RS485-
Negative of RS485 
communication signal
CGND
Ground of RS485 
communication signal
7 V
Power supply to an external 
LCD keypad
Connect an external LCD 
keypad.
The commissioning operation can be performed by connecting the RJ45 interface at the 
back of the external LCD keypad to the RJ45B interface at the top of IS810 using a standard 
network cable. The gure shows the interface of IS810.
The smart operating keypad (model SOP-20) is Inovance's new-generation commissioning 
assistant for the frequency control system and supports products such as IS810, MD810, 
MD880 and HE series and vehicle electronic drives. The smart operating keypad has a wide 
power supply range and LCD display, supports multibus and applies to the single-motor/multi-
motor drive. The keypad provides the functions such as parameter settings, state monitoring, 
simple oscilloscope, parameter copy, fault analysis and locating, program download and USB 
relay.
Figure 4-24 Connection to SOP-20 using an RJ45A interface
For usage details, refer to the 
SOP-20 Smart Operation Panel User Manual
.