EasyManuals Logo

Inovance IS810N-INT Series User Manual

Inovance IS810N-INT Series
290 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
IS810N-INT Series Servo System User Manual (Brief) Chapter 1 Safety Information and Precautions
- 12 -
CAUTION
CAUTION
7. Congure safety devices such as circuit breakers to prevent a short-circuit in the
external circuit. Failure to comply may result in a re.
u
Take appropriate shielding measures in the following scenarios to prevent equipment damages:
1. Interference occurs due to static electricity.
2. There is a strong electric eld or magnetic eld.
3. There may be radiation.
4. Power cables are installed nearby.
1.6 Running Precautions
CAUTION
CAUTION
u
During a trial run, make the servo motor unloaded (not connected to the drive shaft) to
prevent accidents. Failure to comply may result in personal injuries.
u
When the servo motor is installed on a supporting machine, preset user parameters
matching the machine. Running the servo drive without parameter settings may make the
machine out of control or cause faults.
u
During home return, the forward limit switch (P-OT) and reverse limit switch (N-OT) signals
are inactive.
u
When the servo motor drives the vertical axis, congure a safety device to prevent the work
from falling on conditions such as warning or sensing the limit switch. Set servo off when
the motor senses the limit switch to prevent the work from falling.
u
When online auto-tuning is not used, set the correct load inertia ratio to prevent vibration.
u
After power-on or within a short time after power-off, do not touch the heatsink of the servo
drive, external regenerative resistor, and servo motor as they may get very hot. There is a
risk of burns.
u
Inappropriate user parameter adjustment makes the servo system instable. Do not perform
such operations. Failure to comply may result in personal injuries.
u
When a warning occurs, resolve the causes and ensure safety before resetting the warning,
and then start running again. Failure to comply may result in personal injuries.
u
Do not use the motor's own brake for general braking. Failure to comply may result in faults.
1.7 Maintenance Precautions
CAUTION
CAUTION
u
Only by professional personnel are allowed to turn on/off the power switch.
u
When performing the insulation resistor test on the drive, disconnect all connections to the
drive. Otherwise, faults will occur in the drive.
u
Do not use oil, diluent, alcohol, or acid or alkaline detergent to prevent housing discoloring
or damages.
u
When replacing the drive, migrate the user parameters of the drive to be replaced to the
new drive, and then run the new drive. Otherwise, the drive may be damaged.
u
Do not change wiring when the drive is live. Failure to comply may result in electric shocks
or personal injuries.
u
Do not dismantle the servo motor. Failure to comply may result in electric shocks or
personal injuries.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance IS810N-INT Series and is the answer not in the manual?

Inovance IS810N-INT Series Specifications

General IconGeneral
BrandInovance
ModelIS810N-INT Series
CategoryServo Drives
LanguageEnglish

Related product manuals